text.skipToContent text.skipToNavigation

{{ addToCartData.mixPtRmWarning }}

Czy chcesz kontynuować?

{{requestQuote.productName}}; {{requestQuote.form.productCode}}

Dziękujemy

Wkrótce odpowiemy na Twoje zapytanie.

Something went wrong, please try again later.

Zamówienie zbiorcze
Jeśli nie, kliknij „Anuluj”. Możesz również zapisać ten artykuł na później.
Anuluj
Jeśli nie, kliknij „Anuluj”. Możesz również zapisać ten artykuł na później.
Anuluj

What's your flash point?

lantern

 

Flash point is the lowest temperature at which a liquid (usually a petroleum product) will form a vapor in the air near its surface that will “flash,” or briefly ignite, on exposure to an open flame. Back in the late 1800s, flash point was a lived experience. Households primarily used kerosene for heat and light, and open flame was a part of every day. Bad kerosene – fuel diluted with gasoline or other contaminants – delivered unpredictable flash points and bad results. Fires and explosions were fairly common. These shared catastrophes ushered in a focused effort to establish meaningful standards for various grades of petroleum. Both ASTM (ASTM D56, ASTM D92 and ASTM D93) and OSHA (OSHA's 29 CFR 1910.106 standard) have created standard flash point measurement methods that are used today.

 

The standardization of flash point analysis fundamentally created a durable definition for flash point relative to the type of fuel considered. For example,

 

 - Automotive gasoline,−43 °C (−45 °F)

 

 - Ethyl alcohol, 13 °C (55 °F)

 

 - Automotive diesel fuel, 38 °C (100 °F) 

 

 - Kerosene, 42-72 °C (108 - 162 °F) 

 

 - Home heating oil, 52-96 °C (126-205 °F)

 

 - SAE 10W-30 motor oil, 216 °C (421 °F)

 

Flash points are measured using one of two methods: closed cup or open cup. Either of these methods, when executed properly, deliver a precise characterization of the fuel tested, and are extremely important to identify contaminants in the fuel, especially those contaminants that are more volatile than the fuel itself. Like so many things, fuels can experience significant performance or monetary value changes due to contamination. Flash points are critical data points for quality assurance, and flash point analysis is a strong tool when used routinely to keep petroleum-based products true to grade. 

 

The recent acquisition of Paragon Scientific by LGC means our flash point standard portfolio is more comprehensive than ever and includes a range of CRMs suitable for Pensky Martens and Cleveland Open Cup techniques! Our flash point certified reference materials are certified in accordance with international test method protocols, including ASTM, and are fully traceable to international standards. Explore our range to learn more about our flash point CRMs.

Punchout session timeout warning

Your punchout session will expire in1 min59 sec.

Select "Continue session" to extend your session.